2020 Wacker Neuson E3000 Ground Heater w/ Generator

2020-Wacker-Neuson-E3000-Ground-Curing-Construction-Heating-Concrete-Curing-Ground-Heater-Generator

2020 Wacker Neuson E3000 Ground Heater w/ Generator

2020 Wacker Neuson E3000

Hours:1,083.2

Diesel Fired

385,000 BTU’s

2” Ball

Onboard 6Kw Kohler Diesel Generator

-Hours: 1,109.5

-Fully enclosed

-Powers machine to make it useable on any jobsite

Dual rear hose set up

One pump per hose loop means delivery of maximum Btu’s per hour.

Engineered for reliable performance and trouble-free starts

up to 140 hours of run time

the E3000 will provide maximum flow and ensure consistent heat delivery for thawing and curing applications.

The E3000 thaws or cures up to 6,000 sq. ft. With accessories this heater will cure up to 18,000 sq. ft. or provide 535,000 cu. ft. of dry heat at 83% efficiency, the highest in the industry.

With 3,000 ft. of hose and a hydraulic hose system, the E3000 allows for single person set-up and placement, for greater flexibility on all applications.

Positive displacement pump provides maximum flow and consistent heat delivery for thawing and curing.

Digital temperature controller with push button adjustment allows operators to easily adjust Heat Transfer Fluid (HTF) output temperature for all concrete curing applications.

Unit is fully functional and has just been serviced!

2020 Wacker Neuson E3000 Ground Heater w/ Generator

2020-Wacker-Neuson-E3000-Ground-Curing-Construction-Heating-Concrete-Curing-Ground-Heater-Generator

2020 Wacker Neuson E3000 Ground Heater w/ Generator

2020 Wacker Neuson E3000

Hours:730

Diesel Fired

385,000 BTU’s

2” Ball

Onboard 6Kw Kohler Diesel Generator

-Hours: 856.7

-Fully enclosed

-Powers machine to make it useable on any jobsite

Dual rear hose set up

One pump per hose loop means delivery of maximum Btu’s per hour.

Engineered for reliable performance and trouble-free starts

up to 140 hours of run time

the E3000 will provide maximum flow and ensure consistent heat delivery for thawing and curing applications.

The E3000 thaws or cures up to 6,000 sq. ft. With accessories this heater will cure up to 18,000 sq. ft. or provide 535,000 cu. ft. of dry heat at 83% efficiency, the highest in the industry.

With 3,000 ft. of hose and a hydraulic hose system, the E3000 allows for single person set-up and placement, for greater flexibility on all applications.

Positive displacement pump provides maximum flow and consistent heat delivery for thawing and curing.

Digital temperature controller with push button adjustment allows operators to easily adjust Heat Transfer Fluid (HTF) output temperature for all concrete curing applications.

Unit is fully functional and has just been serviced!

2010 Dryair Greenthaw 600GTS Ground Heater w/ Generator

2010-Dryair-Greenthaw-600GTS-Ground-Curing-Construction-Heating-Concrete-Curing-Ground-Heater

2010 Dryair Greenthaw 600GTS Ground Heater w/ Generator

2010 Dryair 600GTS

Hours: 2,218

Diesel Fired

Pintle Hitch

Onboard 7KW Kubota Diesel Powered Whisper Watt Generator

-Fully Enclosed

-Powers machine to make it useable on any jobsite

-Phase: 1

-120/240

620k BTU Heater

4,000’ of hose

-Power Reel (In and out)

THAW AREA – 6,000 ft² (std), 11,200 ft² (w/acc)

CURE AREA – 8,000 ft² (std), 25,000 ft² (w/acc)

The large 620,000 BTU heater provides you with ample BTU’s for ground thaw, concrete cure & space or fluid heating applications

Patented Flow Reverser  – Eliminates hot and cold zones in the thaw pattern

Reduces time & fuel costs by up to 50%

Consistent curing temperatures across the entire slab means the whole slab cures at the same rate

Patented Combustion Environment Control System preheats the fuel and air used for combustion

No need to bring it in to a heated shop before it goes out on the job.  The preheater allows the unit to start & run even in sub 40 degree conditions

Industry leading multi-loop ground thaw set-up for job site flexibility and optimum fluid circulation & heat transfer

Manifold System allows for fan coils or heat exchangers to plug in for space heating or fluid heating

Unit is fully functional and ready to go to work!

2014 Thor LD5030 Enclosed Ground Heater Construction Heater Concrete Curer w/ Generator

2014-Thor-LD5030-Ground-Heater-Concrete-Curing-Construction-Heater-Ground-Heater-Machine-W/-Generator

2014 LD5030 Enclosed Ground Heater Construction Heater Concrete Curer w/ Generator

2014 Thor LD5030

Hours: 5,072

Boiler 329,000 BTU

Fuel Capacity 120 US gals

Heat Transfer Propylene Glycol/Water

Fluid Reservoir 78 US gals

Hose Length (3) 1000ft loops

Hose Rating 200 PSI

Electrical Requirements 30 amp, 120V

Trailer 6×12 Tandem Axel\

Onboard Multiquip DA-7000 Diesel Generator

The control panel features large, easy to use switches, digital supply and return temperature controls with warning and operation lights for all components. The entire system is protected by a ground fault interrupt breaker and is CSA certified for safety assurance.

Kubota Diesel

Hours: 5,224

7Kw

120v/240v

60hz

Single phase

Unit is fully functional and has just been fully serviced!